Node details //features
These rules are applied, identically, at different points in the feed:
Properties
//property/features
Real estate at auction
//auction/estates/estate/features
//features
Contentiore of basic descriptive features of the property.
//features/rooms-detail/amount-bedrooms
number of bedrooms
//features/rooms-detail/amount-other-rooms
number of other rooms (excluding bedrooms and bathrooms)
//features/rooms-detail/kitchen
type of kitchen.
Allowable values are:
- Abitabile
- Semi abitabile
- Cucinotto
- Angolo cottura
- A vista
//features/sizes
Container for textures
Attribute | Description | Status |
---|---|---|
@unit | Units of measurement, to be enhanced with m2 | Mandatory |
Exceptional cases
Some property types use the consistencies to define on which floors the property is located. For them, weight and area should be valued with 0
(zero).
Garage (253) or parking space (254).
Only permitted consistency Garage
.
Coworking space (259)
Only permitted consistency Office
.
//features/sizes/size
Consistency record
Attribute | Description | Status |
---|---|---|
@main | Main consistency. If true is used to calculate total area. | Flag ``(true |
//features/sizes/size/type
Consistency type.
Please note - Depending on the immobililiare type, some types of consistencies are not allowable: refer to the available list.
Complete list of possible values:
- Abitazione
- Appartamento
- Ufficio
- Negozio
- Magazzino
- Garage
- Cantina
- Soffitta
- Balcone
- Terrazzo
- Giardino
- Terreno
- Parti comuni
- Altro
- Mansarda
- Capannone
- Laboratorio
- Posti auto
- Posto auto
- Soppalco
- Esterno
- Parcheggio
- Albergo/hotel
- Posto moto
- Posto barca
- Posto camper o roulotte
- Autorimessa
- Centralina
- Podere o tenuta
- Filiale bancaria
- Scuderia
- Casa di cura
- Stabilimento balneare
- Azienda agricola
- Impianti sportivi
- Stazione di servizi
- Autorimessa
- Autolavaggio
- Campeggio
- Piazzale
- Locale tecnico
//features/sizes/size/floor
Floor definition. The value of //floor/@type
counts, if it is worth "Intermediate" or is absent the numeric value (0 for ground floor) counts instead.
Attribute | Description | Status |
---|---|---|
@type | descriptive value of the floor |
@type
takes the values:
- Intermedio
//floor
- Interrato(-1)
- Interrato(-2)
- Interrato(-3)
- Interrato(-4)
- Interrato(-5)
- Seminterrato
- Controterra (alias PianoTerra)
- PianoTerra
- Rialzato
- Ammezzato
//features/sizes/size/surface
valore della superficie di questa consistenza
//features/sizes/size/weight
Weight of the consistency in percentage (p), if different from 100 the area (s) of the consistency will weigh on the total computation (pt) according to the formula:
pt = s * p / 100
However, in order to contribute to the computation of the total area of the property, the consistency must be marked as principal //sizes/size/@main
//features/size
Floor area of the property (to be omitted if the table of consistencies is present: the total value of the floor area of the property will be calculated from them)
Attribute | Description | Status |
---|---|---|
@unit | Units of measurement, to be enhanced with m2 | Mandatory |
//features/descriptions
Property descriptions separated by language
//features/descriptions/description
Property description
Attribute | Description | Status |
---|---|---|
@language | description language | Mandatory |
For language use the two-character ISO 639-1 standard. Italian is it
//features/descriptions/description/title
Title of the listing (max 255 characters)
//features/descriptions/description/content
Description text
//features/energy-class
Information on energy class and heat loss. Information on the energy class of the building is required by law.
Caution: Certain categories (land, warehouses, and garages) for which no form of air conditioning is provided are exempt. In such cases, the node, which remains mandatory, should be created with only the exemption indication.
<energy-class value="esente" />
Attribute | Description | Status |
---|---|---|
@zero | zero-energy building | |
@scale | 2= APE certification (recommended), 1= IPE certification prior to Oct. 1, 2015 | |
@value | energy class | Mandatory |
@certified | indicates whether the building has been certified or is awaiting energy certification |
possible values for @value
with APE Certification:
possible values for @value
with IPE Certification (up to October 2015):
finally, two special values are provided for exempt or unclassifiable properties.
//features/energy-class/energy-performance
Energy performance information
Attribute | Description | Status |
---|---|---|
@unit | unit of measurement (kWh/m2year or kWh/m3year) | |
@type | type |
possible values for @type
:
- nren (from non-renewable energy)
- ren (from renewable energies)
//features/energy-class/energy-season
list of seasonal energy performance
Attribute | Description | Status |
---|---|---|
@season | season | |
@level | performance level |
possible values for @season
:
- summer
- winter
possible values for @level
:
- low
- normal
- high
//features/energy-class/emissions-class
describes the property's emission information
Attribute | Description | Status |
---|---|---|
@value | emission class |
possible values for @value
:
Back to main page
2025 Indomio.com